Switchgear · Air-insulated

ROBUST I

Withdrawable metal-enclosed switchgear for distribution, control, metering, and protection in medium-voltage networks.

12 / 17.5 / 24kV
up to 4,000A
up to 40kA
ROBUST I medium-voltage panelSeries Air-insulated Switchgear
01 / Overview

Safe distribution.
Reliable operation.

ROBUST I is designed to receive and distribute power in three-phase AC networks from 3.6 to 24 kV at 50 or 60 Hz.

It integrates circuit control, metering, and detection functions and can be used in single-busbar and sectionalized-busbar systems. The withdrawable unit accommodates vacuum circuit breakers and vacuum contactors.

Nexgrid medium-voltage panel designed for safe operation
02 / Design and safety

Built to
protect and respond.

01

Reinforced modular structure

Side panels with double inward folds and a frame joined with stamped rivets. Elements can be replaced individually to reduce recovery time.

02

Rapid pressure relief

Hinged top cover with nylon fasteners and an internal corrugated grille to facilitate pressure relief and limit the ejection of arc-generated particles.

03

Reliable interlocks

The upper rear door cannot open while the lower door is closed; the lower door cannot close while the upper door is open. The grounding interlock supports manual or motorized operation without changing parts.

04

Protected secondary control

All-metal secondary wiring channels help maintain signal transmission and facilitate rapid fault clearing.

03 / Technical specifications

Three voltage levels.
One robust platform.

Reference ratings. Final configuration depends on project conditions.

Parameter12 kV17.5 kV24 kV
Rated frequency50 / 60 Hz50 / 60 Hz50 / 60 Hz
Rated current≤4,000 A≤3,150 A≤3,150 A
Power-frequency withstand voltage, 1 min28 kV38 kV50 kV
Lightning impulse, peak75 kV95 kV125 kV
Short-circuit breaking current40 kA31.5 kA31.5 kA
Short-circuit making current100 kA80 kA80 kA
Withstand current40 kA / 3 s31.5 kA / 3 s31.5 kA / 3 s
Enclosure protectionIP4XIP4XIP4X
Compartment protectionIP2XIP2XIP2X
Service continuityLSC2BLSC2BLSC2B
Permissible internal arc duration1 s1 s1 s
Temperature-rise testIrIrIr
Peak withstand current100 kA80 kA80 kA
Power-frequency withstand voltage of auxiliary and control circuits2 kV2 kV2 kV
CoolingNatural*Natural*Natural*

* Air cooling must be used for rated currents ≥3,150 A, according to the brochure.

04 / Enclosure dimensions

Dimensions for
every configuration.

Dimensions in millimeters. Dimensions by voltage level as listed in the ROBUST I brochure.

Cabinet typeWidth W (mm)Depth D (mm)Height H (mm)
ROBUST I · 12 kV400, 500, 6001 / 650, 800, 1,0001,450, 1,610, 1,7502,240
ROBUST I · 17.5 kV8002 / 1,00021,650, 2,0002,240
ROBUST I · 24 kV8002 / 1,0001,800, 2,2002,400

1. Bus riser cabinet. 2. Rated current below 1,250 A.

05 / Service conditions
+40 °CMaximum ambient temperature
−15 °CMinimum ambient temperature
≤1,000 mReference altitude
≤95%Daily relative humidity
≤90%Monthly relative humidity
25 KMaximum daily temperature difference
III / CPollution level III, equivalent to C
0.2 gHorizontal seismic capability

Conditions outside these values are considered special and can be adapted to actual project requirements.

06 / Configure ROBUST I

Let's define the panel
for your application.

Share your project's voltage, current, short-circuit capacity, diagram, and service conditions.