Switchgear · Air-insulated

ROBUST II

Withdrawable metal-enclosed switchgear for distribution, control, metering, and protection in medium-voltage networks.

40.5kV
up to 3,150A
31.5kA
ROBUST II medium-voltage panelSeries Air-insulated Switchgear
01 / Overview

Safe distribution.
Reliable operation.

ROBUST II is designed to receive and distribute power in three-phase AC networks up to 40.5 kV at 50 or 60 Hz.

It integrates circuit control, metering, and detection functions and can be used in single-busbar and sectionalized-busbar systems. The withdrawable unit accommodates vacuum circuit breakers.

Nexgrid medium-voltage panel designed for safe operation
02 / Design and safety

Built to
protect and respond.

01

Grounding interlock

New interlock with low operating force, long service life, and high stability, designed to simplify assembly, commissioning, and maintenance.

02

Adaptable limit switch

Device that compensates for adjustment clearances in the front, rear, and lateral directions within a ±5 mm range.

03

Secondary interlock

Adapted to a truck travel of 510–610 mm, with 58- and 46-pin connectors compatible with the mechanisms described in the brochure.

04

Internal busbar layout

The internal layout maintains the exterior dimensions and allows air clearances ≥300 mm at busbars and their connections; the brochure excludes phase-to-phase clearance.

05

Reinforced truck

Truck base with a rail structure, manufactured using a dedicated welding fixture for reinforcement and stability.

06

Protected secondary circuits

All-metal channels protect secondary wiring from arcs and maintain signal transmission to the protection system for rapid fault clearing.

03 / Technical specifications

40.5 kV.
Capacity and continuity.

Reference ratings. Final configuration depends on project conditions.

ParameterValue
Rated voltage40.5 kV
Rated frequency50 / 60 Hz
Rated current≤3,150 A
Temperature-rise testIr
Power-frequency withstand voltage, 1 min95 kV
Lightning impulse, peak185 kV
Short-circuit breaking current31.5 kA
Short-circuit making current80 kA
Withstand current and duration31.5 kA / 3 s
Peak withstand current80 kA
Power-frequency withstand voltage of auxiliary and control circuits2 kV
Enclosure protectionIP4X
Compartment protectionIP2X
Service continuityLSC2B
CoolingNatural*
Permissible internal arc duration1 s

* Air cooling must be used for rated currents ≥3,150 A, according to the brochure.

04 / Enclosure dimensions

Dimensions for
every configuration.

Dimensions in millimeters. Configurations identified by height, according to the ROBUST II brochure dimensions.

Cabinet typeWidth W (mm)Depth D (mm)Height H (mm)
ROBUST II · height 2,000 mm1,200* / 1,4002,800, 3,0002,000
ROBUST II · height 2,400 mm1,2002,800, 2,6002,400

* Width of 1,200 mm for rated current ≤1,250 A in the ROBUST II cabinet · height 2,000 mm.

05 / Service conditions
+40 °CMaximum ambient temperature
−15 °CMinimum ambient temperature
≤1,000 mReference altitude
≤95%Daily relative humidity
≤90%Monthly relative humidity
25 KMaximum daily temperature difference
III / CPollution level III, equivalent to C
0.2 gHorizontal seismic capability

Conditions outside these values are considered special and can be adapted to actual project requirements.

06 / Configure ROBUST II

Let's define the panel
for your application.

Share your project's voltage, current, short-circuit capacity, diagram, and service conditions.